40 KW John Deere Diesel Generator 40 Kva – 1 Phase, 60HZ SDMO J40UM

40 KW John Deere Diesel Generator 40 Kva – 1 Phase, 60HZ SDMO J40UM

JOHN DEERE 3029TF120 DIESEL ENGINE, Heavy duty Turbocharging, Mechanical governing (Electronic option), 1800rpm, Liquid cooled

60KW LEROY SOMER ALTERNATOR, brushless, IP23 drip-proof protected, insulation class H. Auto voltage regulation with R250 AVR

LARGE METALLIC FUEL TANK, incorporated in the chassis for 12 hours continuous runtime at 75% power, or 9 hours at 100% power

SDMO NEXYS CONTROL, Digital control with auto Start/Stop capability. All alarms, parameters, controls, shutdowns, and indicators, CE and UL

40 KW John Deere generator 40 KVA, OPEN and SILENT

40 KW JOHN DEERE GENERATOR, SINGLE PHASE, FULLY PACKAGED INCLUDES:

  • Open version, OPTIONAL: IP56 rated Weather proof, silent enclosure. 12 gauge electro zinc coated steel for maximum corrosion resistance
  • 2 wire Auto Start/Stop control feature included for optional operation with ATS/AMF
  • 100L (26Gal) Incorporated metallic fuel tank with gauge, single wall: (12hours @ 75%) (9hours @ 100%)
  • SCHNEIDER 3 pole Main circuit breaker installed and max output rated for complete generator protection
  • 10dB(A) Industrial silencer, OPTIONAL: 29dB(A) Critical class silencer installed inside the enclosure
  • Single bearing alternator, IP23 Ingress Protection, Insulation class H, SR7 AVR, +/- 1.5% regulation
  • Mechanically welded steel chassis with forklift pockets and anti-vibration isolators
  • Radiator cooling system for wiring Temperature of 52°C [122°F] max and -32°C [-25.6°F] min, with fan
  • 12V charging alternator and starter motor
  • 12V electrolyte charged DC starting battery secured to the chassis with cables
  • Air filter, spin-on fuel filter and oil filter elements installed
  • Each generator is individually factory load bank tested to 110% rated power prior to shipping
  • User guide, commissioning and maintenance manual with Wiring diagrams included
  • The generator accepts 100% rated load in one step as per NFPA110 and meets ISO8528-5
  • Complies to ISO3046, ISO8528, BS5514, BS5000PT99, AS1359, BS4999, IEC34, UTE5100, VDE0530 and ISO 9001:2008

JOHN DEERE GENERATOR 40KW, 40KVA, 3PHASE, 60HZ PRICE USD
•J40UM generator “OPEN” $Quote TODAY
•J40UMIV generator “WEATHER / SILENT ENCLOSURE” $Quote TODAY
GENERATOR ACCESSORIES AND OPTIONS
•ATS, 2POLE, NEMA1 Indoor, UL1008, ASCO auto transfer switch
•ATS, 2POLE, NEMA3R Outdoor, UL1008, ASCO auto transfer switch
•56GAL, 25 HOURS, 1WALL, subbase metallic fuel tank
•MAINTENANCE KIT 1: 1000 HOURS, original Oil/Air/Fuel filter(s) kit
•MAINTENANCE KIT 2: 2000 HOURS, original Oil/Air/Fuel filter(s) kit
•BATTERY CHARGER KIT: 12V Automatic Battery Charger kit
•FUEL FILTRATION KIT: Racor water-fuel separator and impurities kit
•ENGINE EXERCISER KIT: 24/7 Programmable schedule timer
•ENGINE PREHEATER KIT: Hotstart engine heater for cold weather
•ROAD TRAILER: 3500LBS GVWR, DOT compliant, generator trailer
STOCK / LEAD TIME
•In stock, 1-2 days subject to previous sales. Need a formal quote?

John Deere Generator 3029TF120 Turbo Diesel Engine

Best in class fuel economy, Heavy duty 1800rpm, and fully manufactured in America/Europe, John Deere generator engines have proven highly cost effective in a variety of power generation applications from Standby and residential to Prime and industrial.

Available both in U.S. EPA compliant and Export only models, 50HZ and 60HZ, Over 100,000 customers worldwide from Alaska to Australia are currently trusting John Deere generators for all their power needs, you can too.

40 KW John Deere generator diesel engine

PERFORMANCE DATA
Frequency (Speed): 60 Hz (1800 rpm)
Prime: 43 kW (58 hp)
Standby: 48 kW (64 hp)
GENERAL DATA
Bore x Stroke–in. (mm): 106 x 110 (4.17 x 4.33)
Compression Ratio: 17.2:1 Aspiration: Turbocharged

SDMO Digital Auto Start/Stop Control options

SDMO NEXYS digital control panelThe NEXYS is a versatile control for operation in manual or automatic mode. Equipped with an LCD screen, the user-friendly interface offers high-quality basic functions to guarantee simple, reliable operation of your generator. Electrical measurements: voltmeter, frequency meter, ammeter. Engine parameters: working hours counter, engine speed, battery voltage, fuel level. Alarms and faults: oil pressure, coolant temperature, failure to start, overspeed, charging alternator fault, low fuel level, emergency stop.And many more features, please visit Downloads SDMO TELYS 2 digital control panelThe advanced TELYS 2 control is complex yet accessible, thanks to the engineering of its ergonomics and ease of use. With its large display screen, buttons and scroll wheel, it emphasizes simplicity and communication. Electrical measurements: voltmeter, frequency meter, ammeter. Engine parameters: working hours counter, oil pressure, coolant temperature, fuel level, engine speed, battery voltage. Alarms and faults: oil pressure, coolant temperature, failure to start, overspeed, alternator min./max., battery voltage min./max., emergency stop, fuel level. Communication: remote control and monitoring, USB connection, PC connection.And many more features, please visit Downloads