LISTER PETTER LPWS3 DIESEL ENGINE, heavy duty, ALPHA series, 4 stroke, 1800rpm, Liquid cooled, Made in the U.K., U.S. EPA Tier i4
LISTER PETTER ALTERNATOR, brushless, IP23 drip-proof protection, Insulation class H. Automatic voltage regulation with SX460 AVR
LARGE FUEL TANK, included standard for 23 hours continuous runtime at 75% power, or 18 hours at 100% power
DEEPSEA 7210 CONTROL, Digital control with optional auto Start/Stop. All alarms, parameters, controls, shutdowns, and indicators, CE and UL
11 KW LISTER PETTER GENERATOR SET FULLY PACKAGED INCLUDES:
- Open version (OR) IP56 rated Weather proof, silent enclosure. 12 gauge electro zinc coated steel for maximum corrosion resistance
- 2 wire Auto Start/Stop control feature included for optional operation with ATS/AMF
- 66L (17Gal) Incorporated polypropylene fuel tank with level gauge, single wall: (23hours @ 75%) (18hours @ 100%)
- 2 poles Main line circuit breaker installed and maximum output rated for complete generator protection
- U.S. EPA Tier i4 compliant engine as per the most strict U.S. Environmental Protection Agency regulations
- 10dB(A) Industrial silencer mounted on the engine (OR) 29dB(A) Critical class silencer installed inside the enclosure
- Single bearing alternator, IP23 Ingress Protection, Insulation class H, SX460 AVR, +/- 1.5% regulation
- Radiator cooling system for wiring Temperature of 52°C [122°F] max and -32°C [-25.6°F] min, with mechanical fan
- 12V charging alternator and starter motor
- 12V electrolyte charged DC starting battery secured to the chassis with cables
- Cartridge type heavy duty 2 stage air filter, spin-on fuel filter and oil filter elements installed
- Galvanized steel chassis mechanically welded with forklift pockets and anti-vibration isolators
- Each generator is individually factory load bank tested to 110% rated power prior to shipping
- User guide, start up and maintenance manual with Wiring diagrams included
- The generator accepts 100% rated load in one step as per NFPA110 and meets ISO8528-5
- Compliant with U.S. EPA Tier i4, BS4999, BS5514, BS5000PT99, AS1359, IEC34, ISO3046, ISO8528, UTE5100, VDE0530 and ISO 9001:2000
| LISTER PETTER GENERATOR LLD140 11KW, 11KVA, 1PHASE, 60HZ |
PRICE USD |
| •LLD140 generator, “OPEN” indoor version |
$Quote TODAY |
| •LLD140(A) generator, “WEATHER / SILENT ENCLOSURE” outdoor version |
$Quote TODAY |
|
|
|
|
| GENERATOR ACCESSORIES AND OPTIONS |
|
| •ATS, 2 POLE, NEMA1 Indoor, UL1008, ASCO auto transfer switch |
|
| •ATS, 2 POLE, NEMA3R Outdoor, UL1008, ASCO auto transfer switch |
|
| •50 GAL (65 HOURS), 2 WALL, UL142 listed, subbase metallic fuel tank |
|
| •MAINTENANCE KIT LVL 1: 1000 HOURS, original Oil/Air/Fuel filter(s) kit |
|
| •MAINTENANCE KIT LVL 2: 2000 HOURS, original Oil/Air/Fuel filter(s) kit |
|
| •BATTERY CHARGER KIT: 12V Automatic Battery Charger Kit |
|
| •FUEL FILTRATION KIT: Racor water-fuel separator and impurities filter |
|
| •ENGINE EXERCISER KIT: 24/7 Programmable schedule timer |
|
| •ENGINE PREHEATER KIT: Hotstart engine heater for cold weather |
|
| •ROAD TRAILER: 3500 LBS (G.V.W.R.), D.O.T. compliant, generator trailer |
|
|
|
|
|
| STOCK / LEAD TIME |
|
| •In stock, 1-2 days subject to previous sales. Request a Quote TODAY! |
|
LPWS2 G-Build Engine
Power range: 11.5; Fixed speed; full-load speeds: 1800 r/min
Special Attributes
- fully emission compliant (see below)
- designed for continuous operation in ambient temperatures up to 52°C (122°F)
- cold-start capability down to -32°C (-25.6°F)
Design Features and Equipment
- heavy-duty air cleaner
- inlet and exhaust manifolds
- inlet manifold heater plugs
- combustion-chamber glow plugs
- fuel lift pump
- self–vent fuel system with individual fuel injection pumps
- fuel filter/agglomerator
|
- gear-driven positive displacement type lubricating oil pump
- spin-on lubricating oil filter
- low oil-pressure switch
- 12V electric start
- flywheel with ring gear
- SAE 5 flywheel housing
- operators’ handbook
|
Deepsea Electronics DSE7210 Auto Start
The DSE7210 is an Auto Start Control Module suitable for a wide variety of single, diesel or gas, gen-set applications.
Monitoring an extensive number of engine parameters, the modules will display warnings, shutdown and engine status information on the back-lit LCD screen and illuminated LEDs.
Both modules are compatible with electronic (CAN) and non-electronic (magnetic pick-up/alternator sensing) engines and offer an extensive number of flexible inputs, outputs and engine protections so the system can be easily adapted to suit a wide range of application demands.
KEY FEATURES
- 4-Line back- lit LCD text display
- Five key menu navigation
- Front panel editing with PIN protection
- LED and LCD alarm indication
- Customisable status screens
- Power save mode
- 7 configurable inputs
- 8 configurable outputs
- Configurable timers and alarms
- 3 configurable maintenance alarms
- Multiple date and time scheduler
- Configurable event log (100)
- Control logic facilities
- Easy access diagnostic page
- CAN and Magnetic Pick-up/Alt. sensing
- Fuel usage monitor and low fuel alarms
- Charge alternator failure alarm
Need a formal Quote? Fill your information on the form below.